Skip to main content
Article
Preserving the pulmonary valve in Tetralogy of Fallot repair: Reconsidering the indication for valve-sparing
Journal of cardiac surgery
  • Umar Siddiqi, Comer Children's Hospital, University of Chicago, Chicago, Illinois, USA.
  • Adedotun Adewale, Advocate Aurora Health
  • Emily Pena, Advocate Aurora Health
  • Kelci Schulz, Advocate Aurora Health
  • Michel Ilbawi, Advocate Aurora Health
  • Chawki El-Zein, Advocate Aurora Health
  • Luca Vricella, Advocate Aurora Health
  • Narutoshi Hibino, Advocate Aurora Health
Affiliations

Advocate Children's Hospital, Advocate Children's Heart Institute

Scholarly Activity Date
12-1-2022
Abstract

Background: Tetralogy of Fallot (TOF) repair is a frequent procedure, and although valve-sparing (VS) repair is preferred, determining which patients can successfully undergo this operation remains controversial. We sought to identify parameters to determine a selective, accurate indication for VS repair.

Methods: We reviewed 71 patients (82%) undergoing VS repair. We analyzed hemodynamic data, intraoperative reports, and follow-up echocardiography results to identify acceptable indications. Patients requiring pulmonary valve (PV) reintervention versus no reintervention were compared.

Results: PV annulus size at repair was z-score of -2.0 (-5.3, 1.3). Approximately half (51%) had a z-score less than -2. Cox regression results showed this was not a risk factor for reintervention (p = .59). Overall, 1-, 3-, 5-, and 10-year freedom from PV reintervention rates were 95.8%, 92.8%, 91% and 77.8%, respectively. Residual pulmonary stenosis (PS) at initial repair was relatively higher in the reintervention group compared with no reintervention group (40 [28, 51] mmHg vs. 30 [22, 37] mmHg; p = .08). For patients with residual PS, pressure gradient (PG) was consistent over time across both groups (PV reintervention: -3 [-15, 8] mmHg vs. no reintervention: 0 [-9, 8] mmHg). The risk of PV reintervention is 3.7-fold higher when the PG from intraoperative TEE is greater than 45 mmHg (p = .04).

Conclusions: Our review of the midterm outcomes of expanded indication for VS suggests intraoperative decision to convert to transannular patch is warranted if intraoperative postprocedure TEE PG is greater than 45 mmHg or RV pressure is higher than half of systemic pressure to prevent reintervention.

Type
Article
PubMed ID
36378940
Citation Information

Siddiqi U, Adewale A, Pena E, et al. Preserving the pulmonary valve in Tetralogy of Fallot repair: Reconsidering the indication for valve-sparing. J Card Surg. 2022;37(12):5144-5152. doi:10.1111/jocs.17156