Skip to main content
Article
Measuring Fifteen Endogenous Estrogens Simultaneously in Human Urine by High-Performance Liquid Chromatography-Mass Spectrometry
Analytical Chemistry
  • Xia Xu
  • Timothy D. Veenstra, Cedarville University
  • Stephen D. Fox
  • John M. Roman
  • Haleem J. Issaq
  • Roni Falk
  • Joseph E. Saavedra
  • Larry K. Keefer
  • Regina G. Ziegler
Document Type
Article
Publication Date
10-15-2005
DOI
10.1021/ac050697c
PubMed ID
16223252
Abstract

A sensitive, specific, accurate, and precise high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for measuring the absolute quantities of 15 endogenous estrogens and their metabolites in human urine has been developed and validated. The method requires a single hydrolysis/extraction/derivatization step and only 0.5 mL of urine, yet is capable of simultaneously quantifying estrone and its 2-, 4-methoxy and 2-, 4-, and 16alpha-hydroxy derivatives, and 2-hydroxyestrone-3-methyl ether; estradiol and its 2-, 4-methoxy and 2-, 16alpha-hydroxy derivatives, 16-epiestriol, 17-epiestriol, and 16-ketoestradiol in pre- and postmenopausal women as well as men. Standard curves are linear over a 10(3)-fold concentration range with the standard error of the estimate (SEE) and the relative standard error of the estimate (RSEE) for the linear regression line ranging from 0.0131 to 0.1760 and 1.2 to 7.3%, respectively. The lower limit of quantitation for each estrogen is 0.02 ng/0.5 mL urine sample (2 pg on column), with the percent recovery of a known added amount of compound (accuracy) of 96-107% and an overall precision, including the hydrolysis, extraction, and derivatization steps, of 1-5% relative standard deviation (RSD) for samples prepared concurrently and 1-12% RSD for samples prepared in separate batches. Since individual patterns of estrogen metabolism may influence the risk of breast cancer, accurate, precise, and specific measurement of endogenous estrogen metabolites in biological matrixes will facilitate future research on breast cancer prevention, screening, and treatment.

Keywords
  • Chromatography,
  • high pressure liquid,
  • estrogens,
  • mass spectrometry,
  • molecular structure,
  • molecular weight
Citation Information
Xia Xu, Timothy D. Veenstra, Stephen D. Fox, John M. Roman, et al.. "Measuring Fifteen Endogenous Estrogens Simultaneously in Human Urine by High-Performance Liquid Chromatography-Mass Spectrometry" Analytical Chemistry Vol. 77 Iss. 20 (2005) p. 6646 - 6654 ISSN: 0003-2700
Available at: http://works.bepress.com/timothy-veenstra/242/