Skip to main content
Article
Variable Rate Heater Control for Livestock Space Heating
Applied Engineering in Agriculture
  • David M. van Utrecht, Iowa State University
  • Steven J. Hoff, Iowa State University
  • Jay D. Harmon, Iowa State University
Document Type
Article
Publication Version
Published Version
Publication Date
1-1-2002
Abstract

An unvented liquid propane–gas (LP) space heater, often used in animal housing, was modified to provide automated variable heat output. As manufactured, the heater had manually–adjusted output settings between 14.7 and 29.3 kW (50,000 and 100,000 Btu/h). The heater was modified by adding a stepper motor and speed reducer to the manual proportioning valve to provide continuous and automated heater output adjustment between 14.7 and 29.3 kW.

Experiments were conducted to compare animal occupied zone (AOZ) velocities, AOZ temperatures, and fuel consumption using on/off and automated variable control modes. These experiments were conducted using inside set point and ambient air temperature differences of 14 and 28C (25 and 50F). All experiments were conducted in the Air Dispersion Laboratory at Iowa State University.

Adding automated variable control reduced the AOZ temperature fluctuations from 5.3C (on/off) to 1.1C (9.5 to 2.0F). In the AOZ, the standard deviation across the entire test room was reduced from 1.4C (on/off) to 0.3C (2.6 to 0.5F). The AOZ airspeed fluctuations were reduced from 10 cm/s (on/off) to 2 cm/s (20 to 4 ft/min). No differences were found in fuel consumption. Results indicate a need for heaters capable of continuous adjustment to even lower energy output levels.

Comments

Journal Paper No. J–18687 of the Iowa Agriculture and Home Economics Experiment Station, Ames, Iowa, Project No. 3140, and supported by Hatch Act and State of Iowa funds

This article is from Applied Engineering in Agriculture 18, no. 2 (2002): 245–253.

Access
Open
Copyright Owner
American Society of Agricultural Engineers
Language
en
File Format
application/pdf
Citation Information
David M. van Utrecht, Steven J. Hoff and Jay D. Harmon. "Variable Rate Heater Control for Livestock Space Heating" Applied Engineering in Agriculture Vol. 18 Iss. 2 (2002) p. 245 - 253
Available at: http://works.bepress.com/steven_hoff/82/