Buoyancy-Driven Air Flow within Plenum-to-Plenum Facility Down-Comer Channel
Experimental Thermal and Fluid Science
  • Mahmoud M. Taha
  • I. A. Said
  • Shoaib Usman, Missouri University of Science and Technology
  • Muthanna H. Al-Dahhan, Missouri University of Science and Technology
Abstract

Reliable measurements of thermal and velocity fields were experimentally investigated under different natural circulation intensities in a dual channel facility designed and developed with a representative geometry of prismatic modular reactor core. Experiments were conducted under steady state conditions to obtain statistically stationary time series signals of temperature and velocity. Insignificant radial temperature variation was observed along the down-comer channel implying that the majority of supplied heat is removed through the upper plenum. Velocity results obtained emphasize the delicate nature of natural circulation phenomena in terms of flow destabilization, and recirculation penetration length. Observed air velocity distribution reveals that downward velocity is proportional to the extent of cooling applied to the setup. The calculated values of the dimensionless group Froude number (Fr) in the range of 2 to 10 indicate that air is dominated by momentum and is exiting the channel as a jet. Quantification of turbulent intensities implies that flow destabilization is noticeable along the down-comer channel particularly for the case of high cooling intensity. For 5°C cooling water temperature, turbulent intensity (vrms/v) peaks at the mid-channel (z/L = 0.5) reaching a value of 0.5. This value of turbulent intensity is much higher than the inlet (z/L = 0.96) and outlet (z/L = 0.04) turbulent intensities of 0.2 and 0.06 respectively. This destabilization is because of the flow reversal and heat conduction effects through stainless steel flanges connecting both channels. Current results provide detailed velocity and temperature variation which can be useful for validating computational fluid dynamics codes.

Department(s)
Nuclear Engineering and Radiation Science
Second Department
Chemical and Biochemical Engineering
Research Center/Lab(s)
Center for High Performance Computing Research
Comments
The authors acknowledge the financial support provided by the U.S. Department of Energy-Nuclear Energy Research Initiative (DOE-NERI) project (NEUP 13-4953 (DENE0000744)) for the 4th generation nuclear energy, which made this work possible.
Keywords and Phrases
  • Hot Wire Anemometry,
  • Natural Circulation Loop,
  • Natural Convection,
  • Passive Safety System,
  • Prismatic Modular Reactor,
  • Temperature and Velocity Measurements
Document Type
Article - Journal
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2018 Elsevier, All rights reserved.
Publication Date
6-1-2018
Publication Date
01 Jun 2018
Citation Information
Mahmoud M. Taha, I. A. Said, Shoaib Usman and Muthanna H. Al-Dahhan. "Buoyancy-Driven Air Flow within Plenum-to-Plenum Facility Down-Comer Channel" Experimental Thermal and Fluid Science Vol. 94 (2018) p. 205 - 214 ISSN: 0894-1777
Available at: http://works.bepress.com/shoaib-usman/94/