Skip to main content
Article
Enlarging the Stokes Shift by Weakening the π-Conjugation of Cyanines for High Signal-To-Noise Ratiometric Imaging
Advanced Science
  • Yongkang Yue, Shanxi University
  • Tingting Zhao, Shanxi University
  • Zhou Xu, Shanxi University
  • Weijie Chi, Hainan University
  • Xiaojun Chai, Second People's Hospital in the City of Linfen
  • Jiahong Ai, Shanxi University
  • Jiawei Zhang, Shanxi University
  • Fangjun Huo, Shanxi University
  • Robert M. Strongin, Portland State University
  • Caixia Yin, Shanxi University
Document Type
Article
Publication Date
11-24-2022
Subjects
  • Organic fluorescent dyes -- Research and Analysis
Disciplines
Abstract

The signal-to-noise ratio (SNR) is one of the key features of a fluorescent probe and one that often defines its potential utility for in vivo labeling and analyte detection applications. Here, it is reported that introducing a pyridine group into traditional cyanine-7 dyes in an asymmetric manner provides a series of tunable NIR fluorescent dyes (Cy-Mu-7) characterized by enhanced Stokes shifts (≈230 nm) compared to the parent cyanine 7 dye (nm). The observed Stokes shift increase is ascribed to symmetry breaking of the Cy-Mu-7 core and a reduction in the extent of conjugation. The fluorescence signals of the Cy-Mu-7 dyes are enhanced upon confinement within the hydrophobic cavity of albumin or via spontaneous encapsulation within micelles in aqueous media. Utilizing the Cy-Mu-7, ultra-fast in vivo kidney labeling in mice is realized, and it is found that the liver injury will aggravate the burden of kidney by monitoring the fluorescence intensity ratio of kidney to liver. In addition, Cy-Mu-7 could be used as efficient chemiluminescence resonance energy transfer acceptor for the reaction between H O and bisoxalate. The potential utility of Cy-Mu-7 is illustrated via direct monitoring fluctuations in endogenous H O levels in a mouse model to mimic emergency room trauma.

Rights

© 2022 The Authors. Advanced Science published by Wiley-VCH GmbH. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

DOI
10.1002/advs.202205080
Persistent Identifier
https://archives.pdx.edu/ds/psu/38953
Citation Information
Yue, Y., Zhao, T., Xu, Z., Chi, W., Chai, X., Ai, J., ... & Yin, C. (2022). Enlarging the Stokes Shift by Weakening the π‐Conjugation of Cyanines for High Signal‐to‐Noise Ratiometric Imaging. Advanced Science, 2205080.