Use of CO2 Concentration Difference or CO2 Balance to Assess Ventilation Rate of Broiler Houses
Transactions of the ASABE
  • Hongwei Xin, Iowa State University
  • Hong Li, Iowa State University
  • Richard S. Gates, University of Illinois at Urbana-Champaign
  • Douglas G. Overhults, University of Kentucky
  • John W. Earnest, Jr., University of Kentucky
Document Type
Article
Publication Version
Published Version
Publication Date
1-1-2009
Abstract

Ventilation rate (VR) is one of the two key elements for quantifying aerial emissions from animal production facilities. Direct, continuous measurement of building VR can be challenging and impractical under certain circumstances, e.g., naturally ventilated animal housing or a large number of ventilation fans in the building. This study examined the suitability of estimating VR of broiler houses with built-up litter (mixture of manure and bedding), when supplemental heating was not in use, through either carbon dioxide (CO 2 ) balance or the relationship of VR to CO 2 concentration difference between exhaust and inlet air. The reference VR was based on direct measurement by continuously monitoring operation of the in-situ calibrated exhaust fans. The comparative analysis of the direct method vs. each indirect method was conducted for a measurement integration time (MIT) of 10, 30, 60, or 120 min. The analyses revealed that MIT of 30 min or greater resulted in non-significant differences in VR between the indirect and direct methods. The broiler building VR (m 3 s -1 ) may be related to the exhaust-inlet CO 2 concentration difference ( ? CO 2 , ppm) as VR ( ± 3.0) = 4456 ( ± 41) ? CO 2 -0.786 ( ± 0.019) at 30 min MIT. The VR may also be determined by the CO2 balance method (including litter CO2 generation) with a correction factor of 0.97 at MIT of 30 to 120 min. If litter CO2 generation is omitted from the total building CO2 production, the actual VR may be estimated by applying a correction factor of 1.077 to the bird respiration CO2 balance VR.. Hence, the CO2 balance or concentration difference method offers a viable alternative or supplemental check for quantifying building VR under certain conditions where direct, continuous VR measurement is not feasible.

Comments

This article is from Transactions of the ASABE 52, no. 4 (2009): 1353–1361.

Access
Open
Copyright Owner
American Society of Agricultural and Biological Engineers
Language
en
File Format
application/pdf
Citation Information
Hongwei Xin, Hong Li, Richard S. Gates, Douglas G. Overhults, et al.. "Use of CO2 Concentration Difference or CO2 Balance to Assess Ventilation Rate of Broiler Houses" Transactions of the ASABE Vol. 52 Iss. 4 (2009) p. 1353 - 1361
Available at: http://works.bepress.com/richard-gates/3/