Gas-Liquid Mass Transfer in a High Pressure Bubble Column Reactor with Different Sparger Designs
Chemical Engineering Science
  • Lu Han
  • Muthanna H. Al-Dahhan, Missouri University of Science and Technology
Abstract

The Gas-Liquid Mass Transfer in a 0.162 M High-Pressure Stainless-Steel Bubble Column Was Investigated using Three Different Gas Sparger Designs. an Oxygen-Enriched-Air Dynamic Method and an Optical Oxygen Probe Technique Were Implemented to Measure K1 a Values in the Bubble Column Reactor. using the Interfacial Area (A) Values Measured by a Four-Point Optical Probe Technique at Similar Conditions (Xue, 2004), the K1 Values Were Estimated. Axial Dispersion Model (ADM) and Continuous Stirred Tank Reactor (CSTR) Model Were Used to Calculate K1 a as a Fitted Parameter with the Measured Data. the ADM Gave Better Fits to the Experimental Data Than the CSTR Model, Especially at High Axial Locations for the Bubble Column Used with a Large L / Dc Ratio. the Sparger Design Was Found to Have a Noticeable Effect on K1 a in the Low Gas Velocity Range (Ug < 0.15 M / S) But Only a Slight Effect in the High Gas Velocity Range (Ug > 0.20 M / S). the Sparger Design Showed Almost No Effect on the Liquid Side Mass Transfer Coefficient, K1, at High Gas Velocity (Ug = 0.30 M / S), Where No Significant Variations of the Bubble Size Distribution and Hydrodynamics Were Obtained using Different Sparger Designs. Although the K1 a Values Increased with the Operating Pressure, the Pressure Change from 0.1 to 0.4 MPa Yielded Lower K1 Values, as a Result of the Reduced Bubble Size. However, as the Pressure Further Increased to 1.0 MPa, the a and K1 a Values Increased, While the K1 Values Negligibly Decreased. in Addition to the Pressure and Sparger Design Effects, the Superficial Gas Velocity Had Effect of Increasing the K1 Values, While Such Effect Became Small and Flattened Out at High Superficial Gas Velocities. © 2006 Elsevier Ltd. All Rights Reserved.

Department(s)
Chemical and Biochemical Engineering
Comments

ConocoPhillips, Grant None

Keywords and Phrases
  • Axial dispersion model,
  • Bubble column,
  • Hydrodynamics,
  • Interfacial area,
  • Mass transfer,
  • Optical oxygen probe
Document Type
Article - Journal
Document Version
Citation
File Type
text
Language(s)
English
Rights
© 2023 Elsevier, All rights reserved.
Publication Date
1-1-2007
Publication Date
01 Jan 2007
Citation Information
Lu Han and Muthanna H. Al-Dahhan. "Gas-Liquid Mass Transfer in a High Pressure Bubble Column Reactor with Different Sparger Designs" Chemical Engineering Science Vol. 62 Iss. 1 thru 2 (2007) p. 131 - 139 ISSN: 0009-2509
Available at: http://works.bepress.com/muthanna-al-dahhan/213/