Skip to main content
Article
A Preliminary Study of the Reliability and Validity of the Posterior Standing Overhead Arm Reach (SOAR) Test as a Measure of Functional Hip Extension Motion
Musculoskeletal Science & Practice
  • Jason K. Grimes, Sacred Heart University
  • Justin C. Wager, Sacred Heart University
  • Jonathan Goldfarb, Physical Therapy Specialists, Guilford, CT
  • Paul Bauer, Physical Therapy Specialists, Guilford, CT
  • Patrick Ferraro, Sacred Heart University
  • Michelle Loken, Sacred Heart University
  • Robert Lynch, Sacred Heart University
  • Tyler Stegmann, Sacred Heart University
Document Type
Peer-Reviewed Article
Publication Date
10-1-2022
Disciplines
Abstract

Background: Current clinical tests do not provide a method to reliably measure closed chain hip extension. We developed the Posterior Standing Overhead Arm Reach (SOAR) test for this purpose.

Objectives: This was a preliminary intrarater and interrater reliability and validity study of the Posterior SOAR test as a measure of functional hip extension.

Design: Cross-sectional.

Method: Hip extension on the Posterior SOAR test was measured with a standard goniometer independently by two examiners. The test was then repeated using three-dimensional (3D) motion capture. Intraclass correlation coefficients (ICC) were used to determine the intrarater and interrater reliability of the goniometric measure and Pearson correlations were used to assess the relationship between measures obtained via goniometry and 3D motion capture.

Results: Fifty hips were assessed in 25 (14 female, 11 male) asymptomatic participants (mean age = 24.0 years, SD = 1.1). Intrarater reliability (ICC2,3) was 0.80 (95% CI = 0.68-0.88) for Examiner 1 and 0.77 (95% CI = 0.64-0.86) for Examiner 2, indicating excellent reliability. The standard error of the measure (SEM90) ranged from 2.5° to 3.0° with a minimal detectable change (MDC90) of 3.5° to 4.2°. Interrater reliability was good with ICC = 0.65 (95% CI = 0.36-0.80). Pearson correlations were significant with low to moderate associations (r = 0.36, P = 0.009; r = 0.51, P < 0.001).

Conclusions: The Posterior SOAR test demonstrated excellent intrarater reliability, good interrater reliability, and low to moderate associations with 3D motion capture. The Posterior SOAR test has the potential to provide a reliable and accurate assessment of closed chain hip extension.

Comments

Available online 25 May 2022.

Patrick Ferraro, Michelle Loken, Robert Lynch, and Tyler Stegmann are graduate students in the Department of Physical Therapy & Human Movement Science at Sacred Heart University.

DOI
10.1016/j.msksp.2022.102589
PMID
35661575
Publisher
Elsevier
Citation Information

Grimes, J., Wager, J., Goldfarb, J., Bauer, P., Ferraro, P., Loken, M., Lynch, R., & Stegmann, T. (2022). A preliminary study of the reliability and validity of the posterior standing overhead arm reach (SOAR) test as a measure of functional hip extension motion. Musculoskeletal Science & Practice, 61(102589). Doi.org/10.1016/j.msksp.2022.102589