Aorto-pulmonary artery disruption following acute type-A aortic dissection repair with the use of BioGlue®.
All Scholarly Works
  • Ak Alameddine, MD, Baystate Health
  • Victor Alimov, MD, Baystate Health
  • John Rousou, MD, Baystate Health
  • Jonathan Freeman, MD, Baystate Health
Document Type
Article, Peer-reviewed
Publication Date
5-1-2012
Abstract

We report an extremely rare complication of a delayed aorto-pulmonary artery wall disruption with false aneurysm formation after repair of acute type-A aortic dissection with BioGlue®. The potential role of BioGlue® in this complication is the subject of this report. © 2012 Wiley Periodicals, Inc.

Publication ISSN
0039-6060
Citation Information
Alameddine A, Alimov V, Rousou J, Freeman J. Aorto-pulmonary artery disruption following acute type-A aortic dissection repair with the use of BioGlue®. J Card Surg 2012 May;27(3):371-3.