Skip to main content
Article
On-chip solid phase extraction and in situ optical detection
Talanta
  • Long Li, East China University of Science and Technology
  • Jibran Iqbal, Zayed University
  • Hui Li, Dehong Teachers’ College
  • Yuan Zhang, East China University of Science and Technology
  • Lin Sun, East China University of Science and Technology
  • Ying Zhu, East China University of Science and Technology
  • Wanchao Chen, East China University of Science and Technology
  • Yongqing Xi, East China University of Science and Technology
  • Ting Wu, East China University of Science and Technology
  • Yiping Du, East China University of Science and Technology
Document Type
Article
Publication Date
5-15-2019
Abstract

© 2019 Elsevier B.V. A device was designed integrating solid phase extraction (SPE) and in situ optical detection techniques. A chip assembled in the device to carry out SPE was enclosed in a fully reflective aluminum box to avoid loss of radiation flux in the optical measurement. The spectrum was measured on the SPE material directly after SPE. The device offers simple analytical operation without any elution step comparing with the traditional analytical methods with complicated procedures. The device and the developed analytical technique was used for the determination of rhodamine B and benzo[a]pyrene with UV–visible diffuse reflectance and solid phase fluorescence spectroscopies, respectively. Under optimal conditions, standard curves of rhodamine B and benzo[a]pyrene showed a linear relationship in concentration ranges of 10–800 μg L-1 (R2 = 0.99) and 0.07–3.33 μg L-1 (R2 = 0.99), respectively. The limit of detections (LOD) were 7 μg L-1 and 0.02 μg L-1. The proposed device was successfully employed to quantify rhodamine B and benzo[a]pyrene in tap water samples. The results showed that the recoveries were 90–105% and the relative standard deviations (RSDs) were 2.53–5.55%, indicating that the device and analytical method is capable of trace analytes for rapid quantitative analysis in various samples.

Publisher
Elsevier B.V.
Disciplines
Keywords
  • Fluorescence spectroscopy,
  • In situ,
  • On-chip SPE,
  • Optical detection,
  • UV–Vis spectroscopy
Scopus ID
85059831119
Indexed in Scopus
Yes
Open Access
No
https://doi.org/10.1016/j.talanta.2019.01.044
Citation Information
Long Li, Jibran Iqbal, Hui Li, Yuan Zhang, et al.. "On-chip solid phase extraction and in situ optical detection" Talanta Vol. 197 (2019) p. 299 - 303 ISSN: <a href="https://v2.sherpa.ac.uk/id/publication/issn/0039-9140" target="_blank">0039-9140</a>
Available at: http://works.bepress.com/jibran-iqbal/40/