Skip to main content
Article
Toxicities, kinetics and degradation pathways investigation of ciprofloxacin degradation using iron-mediated H2O2 based advanced oxidation processes
Process Safety and Environmental Protection
  • Noor S. Shah, COMSATS University Islamabad
  • Allah Ditta Rizwan, COMSATS University Islamabad
  • Javed Ali Khan, University of Peshawar
  • Murtaza Sayed, University of Peshawar
  • Zia Ul Haq Khan, COMSATS University Islamabad
  • Behzad Murtaza, COMSATS University Islamabad
  • Jibran Iqbal, Zayed University
  • Salah Ud Din, University of Azad Jammu and Kashmir
  • Muhammad Imran, COMSATS University Islamabad
  • Muhammad Nadeem, COMSATS University Islamabad
  • Ala'a H. Al-Muhtaseb, Sultan Qaboos University
  • Nawshad Muhammad, COMSATS Institute of Information Technology Lahore
  • Hasan M. Khan, University of Peshawar
  • Moinuddin Ghauri, COMSATS Institute of Information Technology Lahore
  • Gohar Zaman, COMSATS University Islamabad
Document Type
Article
Publication Date
7-1-2018
Abstract

© 2018 Institution of Chemical Engineers Ciprofloxacin (CIP) is a widespread emerging water pollutant and thus its removal from aquatic environment is vital. The use of Fe3+/H2O2 and Fe2+/H2O2 resulted in 38 and 64% removal of CIP (8.0 ppm), respectively, within 80 min reaction time (pH 5.8, [H2O2]0 = 80 ppm, and [iron]0 = 20 ppm). Low pH, high temperature, high dose of H2O2 and Fe2+, and low CIP concentration facilitated removal of CIP. The radical scavenger studies proved in situ generated [rad]OH to be involved primarily in the removal of CIP. The effect of temperature was used to estimate enthalpy and activation energies of the removal of CIP. At 800 min reaction time, the Fe2+/H2O2 resulted in 54% mineralization of CIP using 16.0 ppm [CIP]0, 320.0 ppm [H2O2]0, and 40.0 ppm [Fe2+]0. The potential degradation pathways of CIP established from the degradation of CIP by [rad]OH and products evolved was found to be initiated at C6 through the loss of fluoride ion. The acute and chronic toxicities of CIP and its degradation products were estimated with the final product found to be non-toxic. The results suggest that Fe2+/H2O2-mediated AOPs have high potential for degradation as well as toxicity elimination of CIP and its degradation products.

Publisher
Institution of Chemical Engineers
Disciplines
Keywords
  • AOPs,
  • Ciprofloxacin,
  • Degradation pathways,
  • Toxicity assessment,
  • Water treatment
Scopus ID
85047823281
Indexed in Scopus
Yes
Open Access
No
https://doi.org/10.1016/j.psep.2018.05.020
Citation Information
Noor S. Shah, Allah Ditta Rizwan, Javed Ali Khan, Murtaza Sayed, et al.. "Toxicities, kinetics and degradation pathways investigation of ciprofloxacin degradation using iron-mediated H2O2 based advanced oxidation processes" Process Safety and Environmental Protection Vol. 117 (2018) p. 473 - 482 ISSN: <a href="https://v2.sherpa.ac.uk/id/publication/issn/0957-5820" target="_blank">0957-5820</a>
Available at: http://works.bepress.com/jibran-iqbal/22/