Skip to main content
Article
Wearable Biosensors to Detect Physiologic Change During Opioid Use
University of Massachusetts Medical School Faculty Publications
  • Stephanie Carreiro, University of Massachusetts Medical School
  • Kelley Wittbold, University of Massachusetts Medical School
  • Premananda Indic, University of Massachusetts Medical School
  • Hua (Julia) Fang, University of Massachusetts Medical School
  • Jianying Zhang, University of Massachusetts Medical School
  • Edward W. Boyer, University of Massachusetts Medical School
UMMS Affiliation
Department of Emergency Medicine, Division of Medical Toxicology; Department of Neurology; Department of Quantitative Health Sciences; School of Medicine; Senior Scholars Program
Date
9-1-2016
Document Type
Article
Abstract
INTRODUCTION: Opioid analgesic use is a major cause of morbidity and mortality in the US, yet effective treatment programs have a limited ability to detect relapse. The utility of current drug detection methods is often restricted due to their retrospective and subjective nature. Wearable biosensors have the potential to improve detection of relapse by providing objective, real time physiologic data on opioid use that can be used by treating clinicians to augment behavioral interventions. METHODS: Thirty emergency department (ED) patients who were prescribed intravenous opioid medication for acute pain were recruited to wear a wristband biosensor. The biosensor measured electrodermal activity, skin temperature and locomotion data, which was recorded before and after intravenous opioid administration. Hilbert transform analyses combined with paired t-tests were used to compare the biosensor data A) within subjects, before and after administration of opioids; B) between subjects, based on hand dominance, gender, and opioid use history. RESULTS: Within subjects, a significant decrease in locomotion and increase in skin temperature were consistently detected by the biosensors after opioid administration. A significant change in electrodermal activity was not consistently detected. Between subjects, biometric changes varied with level of opioid use history (heavy vs. nonheavy users), but did not vary with gender or type of opioid. Specifically, heavy users demonstrated a greater decrease in short amplitude movements (i.e. fidgeting movements) compared to non-heavy users. CONCLUSION: A wearable biosensor showed a consistent physiologic pattern after ED opioid administration and differences between patterns of heavy and non-heavy opioid users were noted. Potential applications of biosensors to drug addiction treatment and pain management should be studied further.
Rights and Permissions
Citation: J Med Toxicol. 2016 Sep;12(3):255-62. doi: 10.1007/s13181-016-0557-5. Epub 2016 Jun 22. Link to article on publisher's site
Comments

Kelley Wittbold participated in this study as a medical student in the Senior Scholars research program at the University of Massachusetts Medical School.

Related Resources
Link to Article in PubMed
Keywords
  • Biometrics,
  • Biosensors,
  • Opioids,
  • Signal Processing,
  • Wearables
PubMed ID
27334894
Citation Information
Stephanie Carreiro, Kelley Wittbold, Premananda Indic, Hua (Julia) Fang, et al.. "Wearable Biosensors to Detect Physiologic Change During Opioid Use" Vol. 12 Iss. 3 (2016) ISSN: 1556-9039 (Linking)
Available at: http://works.bepress.com/hua_fang/45/