Abstract

In this paper, we present an enhanced sensitivity of temperature sensors based on thermo-coupled Multicore Fiber (MCF) structures. The sensors are all fabricated using a controlled arc power of a splicing device. Two different principles of a Mach-Zehnder interferometer (MZI) and Michelson interferometer (MI) have been observed experimentally. The MZI and MI structures exhibit temperature sensitivity as 136.67 pm/°C and 70.61 pm/°C, respectively, and found insensitive to the refractive index (RI). Also, its RI response can readily resolve the issues of cross-sensitivity.