CISPR 22: 1997 conducted emission on telecom ports products pass/fail depending on test method
Electromagnetic compatibility
  • K. Hall
  • David Pommerenke, Missouri University of Science and Technology
Abstract
This paper analyzes test result differences for emissions testing in accordance with CISPR22: 1997. Emphasis is laid on unshielded twisted pair cables. It shows potential errors due to imbalance in coupling of the capacitive clamp to the wires of a differential pair and the influence of the common mode source impedance on current clamp and ISN measurements
Department(s)
Electrical and Computer Engineering
Keywords and Phrases
  • Electric Current Measurement,
  • Electric Impedance,
  • Electric Noise Measurement,
  • Electromagnetic Interference,
  • Twisted Pair Cables,