Real-time atomic absorption mercury continuous emission monitor
Review of Scientific Instruments
  • Daniel R. Zamzow, Iowa State University
  • Stanley J. Bajic, Iowa State University
  • David E. Eckels, Iowa State University
  • David P. Baldwin, Iowa State University
  • Chris Winterrowd, ARCADIS
  • Robert Keeney, ARCADIS
Document Type
Article
Publication Version
Published Version
Publication Date
8-1-2003
DOI
10.1063/1.1589158
Abstract

A continuous emission monitor (CEM) for mercury(Hg) in combustor flue gas streams has been designed and tested for the detection of Hg by optical absorption. A sampling system that allows continuous introduction of stack gas is incorporated into the CEM, for the sequential analysis of elemental and total Hg. A heated pyrolysis tube is used in the system to convert oxidizedHg compounds to elemental Hg for analysis of total Hg; the pyrolysis tube is bypassed to determine the elemental Hg concentration in the gas stream. A key component of the CEM is a laboratory-designed and -assembled echelle spectrometer that provides simultaneous detection of all of the emission lines from a Hg pen lamp, which is used as the light source for the optical absorption measurement. This feature allows for on-line spectroscopic correction for interferent gases such as sulfur dioxide and nitrogen dioxide, typically present in combustion stack gas streams, that also absorb at the Hg detection wavelength (253.65 nm). This article provides a detailed description of the CEM system, the characteristics and performance of the CEM, and the results of field tests performed at the Environmental Protection Agency-Rotary Kiln at Research Triangle Park, NC.

Comments

The following article appeared in Review of Scientific Instruments 74, 8 (2003); 3774 and may be found at doi: 10.1063/1.1589158.

Rights
Copyright 2003 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.
Copyright Owner
American Institute of Physics
Language
en
File Format
application/pdf
Citation Information
Daniel R. Zamzow, Stanley J. Bajic, David E. Eckels, David P. Baldwin, et al.. "Real-time atomic absorption mercury continuous emission monitor" Review of Scientific Instruments Vol. 74 Iss. 8 (2003) p. 3774 - 3783
Available at: http://works.bepress.com/david-baldwin/9/