Skip to main content
Article
Airflow Resistance of Cleanings Removed from Corn
Transactions of the ASAE
  • X. Yang, Iowa State University
  • Carl J. Bern, Iowa State University
  • Charles R. Hurburgh, Jr., Iowa State University
Document Type
Article
Publication Version
Published Version
Publication Date
1-1-1990
Abstract

A study was conducted to determine airflow resistance of cleanings removed from corn by screening and by aspiration. Cleanings were divided into fractions and then tested for airflow resistance in a 239-mm-diameter column. Coefficients for the modified Ergun equation were developed to predict airflow resistance of various sizes and size combinations of cleanings for airflows from 0.06 to 30.5 m^/m^ min.

Comments

This article is from Transactions of the ASAE 33 (1990): 1299–1302. Posted with permission.

Access
Open
Copyright Owner
American Society of Agricultural and Biological Engineers
Language
en
File Format
application/pdf
Citation Information
X. Yang, Carl J. Bern and Charles R. Hurburgh. "Airflow Resistance of Cleanings Removed from Corn" Transactions of the ASAE Vol. 33 Iss. 4 (1990) p. 1299 - 1302