Skip to main content
Article
Effectiveness of the "Timed Up and Go" (TUG) and the Chair test as screening tools for geriatric fall risk assessment in the ED.
The American journal of emergency medicine
  • Richard Chow, DO, Lehigh Valley Health Network
  • Andre Lee, USF MCOM-LVHN Campus
  • Bryan G Kane, MD, Lehigh Valley Health Network
  • Jeanne L Jacoby, MD, Lehigh Valley Health Network
  • Robert D Barraco, MD, MPH, Lehigh Valley Health Network
  • Stephen W Dusza, DrPH
  • Matthew Meyers, BS, Lehigh Valley Health Network
  • Marna R Greenberg, DO, MPH, FACEP, Lehigh Valley Health Network
Publication/Presentation Date
6-7-2018
Abstract

OBJECTIVE: We sought to evaluate the effectiveness of the "Timed Up and Go" (TUG) and the Chair test as screening tools in the Emergency Department (ED), stratified by sex.

METHODS: This prospective cohort study was conducted at a Level 1 Trauma center. After consent, subjects performed the TUG and the Chair test. Subjects were contacted for phone follow-up and asked to self-report interim falling.

RESULTS: Data from 192 subjects were analyzed. At baseline, 71.4% (n = 137) screened positive for increased falls risk based on the TUG evaluation, and 77.1% (n = 148) scored below average on the Chair test. There were no differences by patient sex. By the six-month evaluation 51 (26.6%) study participants reported at least one fall. Females reported a non-significant higher prevalence of falls compared to males (29.7% versus 22.2%, p = 0.24). TUG test had a sensitivity of 70.6% (95% CI: 56.2%-82.5%), a specificity of 28.4% (95% CI: 21.1%-36.6%), a positive predictive (PP) value 26.3% (95% CI: 19.1%-34.5%) and a negative predictive (NP) value of 72.7% (95% CI: 59.0%-83.9%). Similar results were observed with the Chair test. It had a sensitivity of 78.4% (95% CI: 64.7%-88.7%), a specificity of 23.4% (95% CI: 16.7%-31.3%), a PP value 27.0% (95% CI: 20.1%-34.9%) and a NP value of 75.0% (95% CI: 59.7%-86.8%). No significant differences were observed between sexes.

CONCLUSIONS: There were no sex specific significant differences in TUG or Chair test screening performance. Neither test performed well as a screening tool for future falls in the elderly in the ED setting.

Disciplines
PubMedID
29910184
Document Type
Article
Citation Information

Chow, R. B., Lee, A., Kane, B. G., Jacoby, J. L., Barraco, R. D., Dusza, S. W., & ... Greenberg, M. R. (2018). Effectiveness of the "Timed Up and Go" (TUG) and the Chair test as screening tools for geriatric fall risk assessment in the ED. The American Journal Of Emergency Medicine, 37(3):457-460. doi:10.1016/j.ajem.2018.06.015