Skip to main content
Article
Treatment of Batch in the Detection, Calibration, and Quantification of Immunoassays in Large-scale Epidemiologic Studies
Epidemiology (2010)
  • Brian W Whitcomb, University of Massachusetts - Amherst
  • Neil J. Perkins
  • Paul S. Albert
  • Enrique F. Schisterman
Abstract
Many laboratory assays measure biomarkers via a 2-stage process. Direct measurement yields relative measures that are subsequently transformed to the unit of interest by using a calibration experiment. The calibration experiment is performed within the main experiment and uses a validation set for which true values are known and relative values are measured by assays to estimate the relation between relative and absolute values. Immunoassays, polymerase chain reaction, and chromatographic approaches are among assays performed in this manner. METHODS: For studies with multiple batches, data from more than a single calibration experiment are available. Conventionally, calibration of assays based on the standard curve is performed specific to each batch; the calibration experiment from each batch is used to calibrate each batch independently. This batch-specific approach incorporates batch variability but, due to the small number of calibration measurements in each batch, may not be best suited for this purpose. RESULTS: Mixed-effects models have been described to address interassay variability and to provide a measure of quality assurance. Conversely, when interbatch variability is negligible, a model that does not incorporate batch effect may be used to estimate an overall calibration curve. CONCLUSION: We explore approaches for use of calibration data in studies with many batches. Using a real data example with biomarker and outcome information, we show that risk estimates may vary depending on the calibration approach used. We demonstrate the potential for bias when using simulations. Under minimal interbatch variability, as seen in our data, conventional batch-specific calibration does not best use information available in the data and results in attenuated risk estimates.
Disciplines
Publication Date
2010
Publisher Statement
The published version is located at http://www.ncbi.nlm.nih.gov/pubmed/21422966
Citation Information
Brian W Whitcomb, Neil J. Perkins, Paul S. Albert and Enrique F. Schisterman. "Treatment of Batch in the Detection, Calibration, and Quantification of Immunoassays in Large-scale Epidemiologic Studies" Epidemiology Vol. 21 Iss. 4 (2010)
Available at: http://works.bepress.com/brian_whitcomb/16/