Skip to main content
Article
Implementation of a New Hysteresis Control Strategy for Autonomous Parallel Active Filter
International Journal of Emerging Electric Power Systems (2006)
  • Tarak Benslimane
  • Kamel Aliouane
  • Boukhmis Chetate
Abstract
The goal of this paper is to evaluate performances of a new hysteresis current control strategy for autonomous three phase parallel active filter in harmonic currents elimination (by simulation an experiment) as well as the reactive power compensation (by simulation). This strategy, called the Optimized Hysteresis Control Strategy, is based on currents errors and their derivatives calculation each time the zero voltage vector is set at the AC side of the inverter of the active filter. The harmonic currents are identified using the method of the instantaneous real and imaginary powers. A voltage regulation loop is used to regulate the condenser DC voltage which ensure a constant DC voltage to the inverter. A digital software C++ simulation program was developed and implemented via the data acquisition board (AT-MIO-16X DAQ from National Instruments). Simulation and experimental results are presented.
Keywords
  • Parallel active filter,
  • Optimized Hysteresis,
  • Two level voltage inverter,
  • reactive power,
  • acquisition card,
  • AT-MIO-16X DAQ.
Publication Date
December, 2006
Citation Information
Tarak Benslimane, Kamel Aliouane and Boukhmis Chetate. "Implementation of a New Hysteresis Control Strategy for Autonomous Parallel Active Filter" International Journal of Emerging Electric Power Systems Vol. 4 Iss. 1 (2006)
Available at: http://works.bepress.com/boukhemis_chetate/1/