Skip to main content
Article
Placement of Intracoelomic Radiotransmitters and Silicone Passive Sampling Devices in Northern Leopard Frogs (Lithobates pipiens)
Journal of Herpetological Medicine and Surgery
  • Taylor J. Yaw, Iowa State University
  • Jennifer E. Swanson, Iowa State University
  • Clay L. Pierce, Iowa State University and United States Geological Survey
  • Erin Muths, United States Geological Survey
  • Kelly L. Smalling, United States Geological Survey
  • Mark W. Vandever, United States Geological Survey
  • Bianca A. Zaffarano, Iowa State University
Document Type
Article
Publication Version
Published Version
Publication Date
12-1-2017
DOI
10.5818/16-10-090.1
Abstract

Historically, wetland toxin exposure studies have relied on single time point samples from stationary sampling devices. Development of passive sampling devices (PSDs) that can be attached to individual animals within wetland habitats has greatly improved in recent years, presenting an innovative sampling technology that can potentially yield individual-specific, quantifiable data about chemical exposure. In this study, silicone based PSDs were attached to the ventral skin of 20 northern leopard frogs (Lithobates pipiens) with polypropylene sutures after radiotransmitters had been surgically implanted into the coleomic cavity. After a short recovery period, frogs were released back into the wetland habitat where they were acquired. The animals were located daily using radiotelemetry to assess how long PSDs would remain attached in the frogs' natural habitat. After one week, PSDs remained on 18 of the original 20 frogs. At two weeks, 17 frogs were recovered and no PSDs remained attached. Although valuable data can be obtained over a short time period, more research will be necessary to demonstrate the effectiveness of externally attaching silicone PSDs to northern leopard frogs for time periods longer than 1–2 weeks.

Comments

This article is published as Yaw, Taylor J., Jennifer E. Swanson, Clay L. Pierce, Erin Muths, Kelly L. Smalling, Mark W. Vandever, and Bianca A. Zaffarano. "Placement of Intracoelomic Radiotransmitters and Silicone Passive Sampling Devices in Northern Leopard Frogs (Lithobates pipiens)." Journal of Herpetological Medicine and Surgery 27, no. 3-4 (2017): 111-115. DOI: 10.5818/16-10-090.1.

Rights
Works produced by employees of the U.S. Government as part of their official duties are not copyrighted within the U.S. The content of this document is not copyrighted.
Language
en
File Format
application/pdf
Citation Information
Taylor J. Yaw, Jennifer E. Swanson, Clay L. Pierce, Erin Muths, et al.. "Placement of Intracoelomic Radiotransmitters and Silicone Passive Sampling Devices in Northern Leopard Frogs (Lithobates pipiens)" Journal of Herpetological Medicine and Surgery Vol. 27 Iss. 3-4 (2017) p. 111 - 115
Available at: http://works.bepress.com/bianca-zaffarano/3/