Effect of Strut Length and Orientation on Elastic Mechanical Response of Modified Body-Centered Cubic Lattice Structures
Proceedings of the Institution of Mechanical Engineers Part L-Journal of Materials-Design and Applications
  • Hasanain Basim Altalebi, Wright State University
  • Ahsan Mian, Wright State University - Main Campus
Document Type
Article
Publication Date
11-1-2019
Find this in a Library

Catalog Record

Abstract

Lattice structures (LSs) have been exploited for wide range of applications including mechanical, thermal, and biomedical structures because of their unique attributes combining the light weight and high strength. The main goal of this research is to investigate the effect of strut length and orientation on the mechanical characteristics of modified body-centered cubic (BCC) LS subjected to a quasi-static axial compressive loading within linear elastic limit using finite element analysis. In this study, two sets of LS were built and analyzed in commercial finite element software, ABAQUS/CAE/EXPLICIT 6.16, using a "smart procedure," which was developed for this research to reduce the computational time and increase the accuracy of results by creating hexahedral mesh elements. The first set comprises 13 models having fixed strut length with strut angle variation from 40 degrees to 100 degrees with a step of 5 degrees. The second set also includes 13 models; however, having variant strut length, kept constant for a single unit cell and through the entire model but varied from one model to another, with the same strut angle variation as the first set. In addition, the BCC LS with a strut angle of 70.53 degrees was replicated in both sets because it was considered as a reference model to compare the results with it. Furthermore, specimens of the reference model were fabricated by a fused deposition modeling- (FDM) based 3D printer using acrylonitrile butadiene styrene (ABS) material and tested experimentally under compression. Experimental results are observed to be in good agreement with those of the finite element simulation, hence the same loading and boundary conditions were adopted for all other models. It was observed that the fixed strut length BCC LS with a strut angle of 100 degrees offers the highest modulus. However, the highest specific strain energy absorption and specific stiffness as well as the least value of weight were dictated by a variant strut length BCC LS with a strut angle of 40 degrees.

DOI
10.1177/1464420719841084
Citation Information
Hasanain Basim Altalebi and Ahsan Mian. "Effect of Strut Length and Orientation on Elastic Mechanical Response of Modified Body-Centered Cubic Lattice Structures" Proceedings of the Institution of Mechanical Engineers Part L-Journal of Materials-Design and Applications Vol. 233 Iss. 11 (2019) p. 2219 - 2233 ISSN: 14644207
Available at: http://works.bepress.com/ahsan-mian/87/