Measurement of plasma cardiac troponin I concentration by use of a point-of-care analyzer in clinically normal horses and horses with experimentally induced cardiac disease

M S. Kraus, Cornell University
Sophy Jesty, University of Tennessee, Knoxville
A R. Gelzer, Cornell University
N G. Ducharme, Cornell University
H O. Mohammed, Cornell University
L M. Mitchell, Cornell University
L V. Solderholm, Cornell University
T J. Divers, Cornell University

Abstract

OBJECTIVE: To compare cardiac troponin I (cTnI) concentrations determined by use of a point-of-care analyzer with values determined by use of a bench-top immunoassay in plasma samples obtained from clinically normal horses with and without experimentally induced cardiac disease, and to establish a reference range for plasma equine cTnI concentration determined by use of the point-of-care analyzer. ANIMALS: 83 clinically normal horses, 6 of which were administered monensin to induce cardiac disease. PROCEDURES: A blood sample was collected from each of the 83 clinically normal horses to provide plasma for analysis by use of the point-of-care analyzer; some of the same samples were also analyzed by use of the immunoassay. All 83 samples were used to establish an analyzer-specific reference range for plasma cTnI concentration in clinically normal horses. In 6 horses, blood samples were also collected at various time points after administration of a single dose of monensin (1.0 to 1.5 mg/kg) via nasogastric intubation; plasma cTnI concentration in those samples was assessed by use of both methods. RESULTS: The analyzer-specific reference range for plasma cTnI concentration in clinically normal horses was 0.0 to 0.06 ng/mL. Following monensin treatment in 5 horses, increases in plasma cTnI concentration determined by use of the 2 methods were highly correlated (Pearson correlation, 0.83). Peak analyzer-determined plasma cTnI concentrations in monensin-treated horses ranged from 0.08 to 3.68 ng/mL. CONCLUSIONS AND CLINICAL RELEVANCE: In horses with and without experimentally induced cardiac disease, the point-of-care analyzer and bench-top immunoassay provided similar values of plasma cTnI concentration.

Suggested Citation

M S. Kraus, Sophy Jesty, A R. Gelzer, N G. Ducharme, H O. Mohammed, L M. Mitchell, L V. Solderholm, and T J. Divers. "Measurement of plasma cardiac troponin I concentration by use of a point-of-care analyzer in clinically normal horses and horses with experimentally induced cardiac disease" American Journal of Veterinary Research 71.1 (2010): 55-59.



This document is currently not available here.

Share