Articles «Previous Next»

Evaluation of Geomembranes Using an Ultrasonic Method

Nazli Yesiller, Wayne State University
Sevil Sungur, DPS Program Manager Team - Detroit

Article comments

Copyright © 2001 ASTM International. The definitive version is available at http://dx.doi.org/10.1520/GTJ11346J.

NOTE: At the time of publication, the author Nazli Yessiler was not yet affiliated with Cal Poly.

Abstract

An ultrasonic testing procedure was developed to evaluate geomembranes. The pulse-echo inspection technique was used on the surface of geomembranes without disturbing the material. The equipment required consists of a P-wave transducer, a pulser-receiver, and a signal acquisition system. Travel time of ultrasonic waves and waveform energy are measured to evaluate the condition of geomembranes. Laboratory tests were conducted to assess the effectiveness of the method. Defects that simulate installation damage and various in-service degradation conditions were induced on samples. The defects were identified with the ultrasonic method at a success rate higher than 98%. Changes in the thickness or the microstructure of the geomembranes were identified. Surficial and internal defects were located. Defects that were not visible from the measurement surfaces were identified. This method appears promising to monitor the condition of geomembranes in the laboratory or in the field and to assess in situ damage to geomembranes.

Suggested Citation

Nazli Yesiller and Sevil Sungur. "Evaluation of Geomembranes Using an Ultrasonic Method" Geotechnical Testing Journal 24.3 (2001): 273-287.
Available at: http://works.bepress.com/nyesille/27