EMP Protection Validation Testing Approaches
Nuclear Survivabiity (1991)
  • George H Baker, James Madison University
Abstract

Integrated, operational system-level testing is required for confidence in any system's EMP hardness. Validation is not possible by analysis or inspection. Test capabilities exist to validate the EMP protection of properly designed systems. High-level free field simulators are the means of choice for testing aircraft and ground mobile systems. A combination of low level continuous wave and pulsed current injection testing are preferred for testing fixed facilities and systems connected to long line networks.

Keywords
  • Electromagnetic Pulse,
  • Protection,
  • Testing,
  • Simulation
Publication Date
February, 1991
Citation Information
George H Baker. "EMP Protection Validation Testing Approaches" Nuclear Survivabiity (1991)
Available at: http://works.bepress.com/george_h_baker/5/