Search All Sites
RSS Feed
Print this page
PDF
This work provides information pertaining to the performance of Silicon-On-Insulator (SOI) microdosimeters in heavy ion...
Measurements were performed to assess the dose equivalent outside a primary proton treatment field, using...
Microdosimetry spectra obtained experimentally utilizing a Silicon-On-Insulator (SOI) microdosimeter within biological materials, was used to...
Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we...
This paper presents in phantom testing of a recently developed intraoperative minidosimetry system, designed to...
The dosimetry of X-ray microbeams using MOSFETs results in an asymmetrical beam profile due to...
The microdosimetric spectra derived by silicon microdosimeter in a proton radiation field traversing heterogeneous structures...
Many new techniques for delivering radiation therapy are being developed for the treatment of cancer....
The irradiation of various tissue-like materials by therapeutic proton beams was simulated using Monte Carlo....
This paper reports on the development of an interactive, intraoperative dose planning system for seed...
Silicon microdosimetry measurements in Fast Neutron Therapy were simulated using the GEANT4 Monte Carlo toolkit....
A heavy ion microprobe was used to conduct ion beam induced charge (IBIC) collection imaging...
New nonionizing energy losses (NIEL) sensors based on silicon planar p-i-n diodes of different geometry...
Preclinical experiments are carried out with ;20–30 mm wide, ;10 mm high parallel microbeams of...
The timing properties of a silicon-on-insulator microdosimeter for medical and space applications have been studied...
In a previous simulation study, we demonstrated the feasibility of using coded apertures together with...
Improvements have been made in the measurement of dose profiles in several types of X-ray...
Presents results of simulations performed as part of the development of a gamma-ray detector module...
In this paper, we report on spectral response data and gamma ray spectroscopy measurements using...
An ion transport code was developed for simulating ionization energy deposition by energetic ions in...
Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires...
A silicon-on-insulator diode array with a sensitive depth of 10 microns has been developed for...
Sufficient skin dose needs to be delivered by a radiotherapy chest wall treatment regimen to...
The depth distribution of the thermal neutron flux is a major factor in boron neutron...
Reverse-biased silicon p-n junction arrays have been proposed as microdosimetry detectors. The tissue equivalence of...
Proton computed tomography has been suggested as a means for maximizing the potential benefits of...
Present Positron Emission Tomography (PET) detectors suffer from degradation of the spatial resolution due to...
Attenuation Correction is important among other corrections for quantitative Positron Emission Tomography (PET). A common...
The response of a solid state microdosimeter based on semiconductor on insulator (SOI) technology to...
As we move into the new millennium, it is important that we improve our understanding...
This article focuses on the characterisation of three versions of a custom designed silicon photodetector...
We have designed and constructed a small animal SPECT system based on compact, high resolution...
We have previously demonstrated the potential of multi-pinhole coded apertures when used in conjunction with...
In this work we report on spectral response data and gamma ray spectroscopy measurements using...