Articles
PDF
Measurements were performed to assess the dose equivalent outside a primary proton treatment field, using...
PDF
Microdosimetry spectra obtained experimentally utilizing a Silicon-On-Insulator (SOI) microdosimeter within biological materials, was used to...
PDF
Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we...
PDF
This paper presents in phantom testing of a recently developed intraoperative minidosimetry system, designed to...
PDF
Edge-on face-to-face MOSFET for synchrotron microbeam dosimetry: MC modeling (with E. A. Siegbahn, E. Brauer-Krisch, A. Holmes-Siedle, M. L. Lerch, A. Bravin, I. Cornelius, G. J. Takacs, N. Painuly, H. Nettleback, and T. Kron), Faculty of Engineering - Papers (2005)
The dosimetry of X-ray microbeams using MOSFETs results in an asymmetrical beam profile due to...
PDF
Microdosimetry simulations of solar protons within a spacecraft (with A. J. Wroe, I. Cornelius, V. L. Pisacane, J. F. Zeigler, M. E. Nelson, F. Cucinotta, M. Zaider, and J. F. Dicello), Faculty of Engineering - Papers (2005)
The microdosimetric spectra derived by silicon microdosimeter in a proton radiation field traversing heterogeneous structures...
PDF
Many new techniques for delivering radiation therapy are being developed for the treatment of cancer....
PDF
The irradiation of various tissue-like materials by therapeutic proton beams was simulated using Monte Carlo....
PDF
This paper reports on the development of an interactive, intraoperative dose planning system for seed...
PDF
Silicon microdosimetry measurements in Fast Neutron Therapy were simulated using the GEANT4 Monte Carlo toolkit....
PDF
A heavy ion microprobe was used to conduct ion beam induced charge (IBIC) collection imaging...
PDF
Neutron dosimetry with planar silicon p-i-n diodes (with M. Yudelev, M. L. Lerch, I. Cornelius, P. Griffin, V. L. Perevertailo, I. E. Anokhin, O. S. Zinets, V. I. Khivrich, M. Pinkovskaya, D. Alexiev, and M. Reinhard), Faculty of Engineering - Papers (2003)
New nonionizing energy losses (NIEL) sensors based on silicon planar p-i-n diodes of different geometry...
PDF
Preclinical experiments are carried out with ;20–30 mm wide, ;10 mm high parallel microbeams of...
PDF
The timing properties of a silicon-on-insulator microdosimeter for medical and space applications have been studied...
PDF
A prototype coded aperture detector for small animal SPECT (with S. R. Meikle, P. Kench, A. G. Weisenberger, R. Wojcik, M. F. Smith, S. Majewski, S. Eberl, R. R. Fulton, and M. J. Fullham), Faculty of Engineering - Papers (2002)
In a previous simulation study, we demonstrated the feasibility of using coded apertures together with...
PDF
Improvements have been made in the measurement of dose profiles in several types of X-ray...
PDF
Presents results of simulations performed as part of the development of a gamma-ray detector module...
PDF
In this paper, we report on spectral response data and gamma ray spectroscopy measurements using...
PDF
An ion transport code was developed for simulating ionization energy deposition by energetic ions in...
PDF
Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires...
PDF
A new silicon detector for microdosimetry applications in proton therapy (with P. Bradley, I. Cornelius, G. I. Kaplan, B. J. Allen, J. B. Flanz, M. Goitein, A. Van Meerbeeck, J. Schubert, J. Bailey, Y. Takada, A. Maruhashi, and Y. Hayakawa), Faculty of Engineering - Papers (2000)
A silicon-on-insulator diode array with a sensitive depth of 10 microns has been developed for...
PDF
Sufficient skin dose needs to be delivered by a radiotherapy chest wall treatment regimen to...
PDF
The depth distribution of the thermal neutron flux is a major factor in boron neutron...
PDF
Reverse-biased silicon p-n junction arrays have been proposed as microdosimetry detectors. The tissue equivalence of...
Presentations
PDF
Present Positron Emission Tomography (PET) detectors suffer from degradation of the spatial resolution due to...
PDF
Attenuation Correction is important among other corrections for quantitative Positron Emission Tomography (PET). A common...
PDF
Response of a SOI Microdosimeter to a /sup 238/PuBe Neutron Source (with M. I. Reinhard, I. Cornelius, D. K. Prokopovich, A. Wroe, V. Pisacane, J. F. Zeigler, M. E. Nelson, F. Cucinotta, M. Zaider, and J. F. Dicello), Faculty of Engineering - Papers (2005)
The response of a solid state microdosimeter based on semiconductor on insulator (SOI) technology to...
PDF
As we move into the new millennium, it is important that we improve our understanding...
PDF
This article focuses on the characterisation of three versions of a custom designed silicon photodetector...
PDF
We have previously demonstrated the potential of multi-pinhole coded apertures when used in conjunction with...
PDF
In this work we report on spectral response data and gamma ray spectroscopy measurements using...